Overview
Quick Details
Place of Origin:
Japan
Brand Name:
Yokogawa
Model Number:
ZR402G
Model:
ZR402G
Measurement object:
Oxygen concentration in combustion exhaust gas and mixed gas
Measurement system:
Zirconia system
Measurement range:
0.01 to 100 vol%O2
Output signal:
4 to 20 mA DC, two points (maximum load resistance 550 Ω)
Sample gas pressure:
-5 to +250 kPa
Probe length:
0.15, 0.4, 0.7, 1.0, 1.5, 2.0, 2.5, 3.0, 3.6,4.2, 4.8, 5.4 m
Contact output:
Four points (one is fail-safe, normally open)
Contact input:
Two points
Power supply:
85 to 264 V AC; 45 to 66 Hz
Packaging & Delivery
Packaging Details
original package
Delivery Time
in stock

Specifications

Yokogawa ZR22G, ZR402G Separate Type Zirconia Oxygen Analyzer
1. original products
2. best price

 

 Yokogawa ZR402G Analyzer ZR402G Zirconia Converter

 

Yokogawa’s zirconia oxygen analyzers are used for combustion monitoring and control in a wide variety of applications and help industries to make considerable achievements in energy saving. The applications range from energy-consuming industries, such as iron and steel, electric power, oil and petrochemical, ceramics, pulp and paper, food, and textiles, to various combustion facilities, such as incinerators and small- and medium sized boilers. Combustion monitoring and control using the analyzer also contribute to a lowering of CO2, SOx, and NOx emissions by allowing for more complete combustion, thus preventing global warming and air pollution.

The ZR402G converter is equipped with an LCD touch screen which has various setting displays, a calibration display, oxygen concentration trend display, with easier operation and improvement of display functions. The converter is equipped with various standard functions such as measurement and calculation as well as maintenance functions including self-test. The ZR22G separate-type detector uses a high-reliability zirconia sensor, and its heater assembly can be replaced on site. The detector is mounted, for example, on the wall of a flue and can measure the gases directly.

 

Features

*The separate type converter ZR402G incorporates a LCD touch-screen for ease of operation.
*The built-in heater assembly of the probe can be replaced on site, reducing maintenance costs.
*The probe uses a long-life, high-reliability Zirconia sensor.
*Remote maintenance using digital communications (HART) reduces maintenance costs.
  
 Note: HART is a registered trademark of HART Communication Foundation.
Yokogawa ZR402G Analyzer ZR402G Zirconia ConverterYokogawa ZR402G Analyzer ZR402G Zirconia Converter
Specifications
Measurement objectOxygen concentration in combustion exhaust gas and mixed gas.
Measurement systemZirconia system
Oxygen concentration0.01 to 100 vol% O2
Output signal4 to 20 mA DC, two points (maximum load resistance 550Ω)
Measurement rangeAny setting in the range of 0 - 5 vol%O2 to 0 - 100 vol%O2 (in 1 vol%O2), or partial range
Digital communication (HART)250 to 550 Ω, depending on number of field devices connected to the loop (multi-drop mode)
Sample gas pressure-5 to +250 kPa
Sample gas temperature0 to 700°C (Probe only)
700 to 1400°C (with 0.15m probe and High Temperature Probe Adapter)
Probe length0.15, 0.4, 0.7, 1.0, 1.5, 2.0, 2.5, 3.0, 3.6,4.2, 4.8, 5.4 m
Contact outputFour points (one is fail-safe, normally open)
Contact inputTwo points
CalibrationMethod ; zero/span calibration
Calibration mode ;
automatic, semi-automatic and manual (All are operated interactively with an LCD touch screen)
Construction of detectorNon-explosion proof. Equivalent to NEMA4X/IP66
Construction of converterOutdoor installation. Equivalent to NEMA4X/IP66
Ambient temperatureProbe: -20 to 150°C
Converter: -20 to 55°C
Power supply85 to 264 V AC; 45 to 66 Hz
 
Performance
Repeatability±0.5% Maximum value of set range
Linearity±1% Maximum value of set range
Drift±2% Maximum value of set range/month
Response time

90% response within 5 sec

Pictures
Yokogawa ZR402G Analyzer ZR402G Zirconia ConverterYokogawa ZR402G Analyzer ZR402G Zirconia Converter
Yokogawa ZR402G Analyzer ZR402G Zirconia Converter
Yokogawa ZR402G Analyzer ZR402G Zirconia Converter
 

 

Company

Yokogawa ZR402G Analyzer ZR402G Zirconia Converter

Why do you choose us?
1. 100% original yokogawa product, 100% quality assurance.
If you find a fake yokogawa. Please contact us without hesitation! We afford the shipment cost! We send you a new product asking zero cent!
2. Varied payment methods.
We adopt  L/C, D/A, D/P, T/T, and other methods. If you can not trust us , you can choose to pay it via Aliexpress! 100% make your money safe!

 

Contact:

Wuhan Xieyuan Automation Equipment Co., Ltd
Telephone:
Mobile Phone:
Fax:
Skype:
Address:6-C9,Caishen Commercial Plaza,Hankou Railway Station